EPSRC Reference: |
EP/K020196/1 |
Title: |
Point-of-Care High Accuracy Fracture Risk Prediction |
Principal Investigator: |
Rogers, Professor K |
Other Investigators: |
|
Researcher Co-Investigators: |
|
Project Partners: |
|
Department: |
Cranfield Defence and Security |
Organisation: |
Cranfield University |
Scheme: |
Standard Research |
Starts: |
30 August 2013 |
Ends: |
21 October 2016 |
Value (£): |
766,251
|
EPSRC Research Topic Classifications: |
Med.Instrument.Device& Equip. |
|
|
EPSRC Industrial Sector Classifications: |
|
Related Grants: |
|
Panel History: |
|
Summary on Grant Application Form |
A significant and escalating worldwide health burden is the aging population and its demand for accurate medical diagnostics. Of particular concern are osteo diseases such as osteoporosis as these become significantly more apparent in elderly populations. Unfortunately, current diagnostic methods are poor predictors of pathology outcomes such as fracture risk. The challenge then is to identify and develop enhanced and new approaches to bone quality appraisal that can be employed for accurate prognosis, targeted therapies and therapy assessment.
It has been well demonstrated that 'bone quality' (including characteristics such as collagen/mineral ratio, collagen integrity, mineral crystallite size, microstrain) has a marked affect on a bone's mechanical properties and is probably the 'missing' information required to produce diagnostically predictive models of fracture. Unfortunately there is no current technique for its in vivo determination. However, such information is embodied within conventional X-ray scatter signatures (e.g. X-ray diffraction) although these are weak and present significant measurement difficulties.
We have identified a potential route to in vivo measurement of these clinically valuable but weak signals. The technology has only recently become available through independent innovations for (i) X-ray generation (flat panel/source-on-a-chip) and (ii) obtaining 'amplified' information from scattered X-rays (using 'focal construct technology', FCT). Critically, the multi-emitter flat panel X-ray source will enable us to engineer precisely the analytical X-ray beam required to provide scatter signatures enhanced by several orders of magnitude. The FCT beam topology also enables the simultaneous measurement of the absorbed X-rays (to estimate bone mineral density) and those coherently (and incoherently) scattered. The source-on-a-chip technology is manufactured as a flat-panel device capable of generating X-rays from very low-power sources. It has the additional advantage that it may be fabricated to produce an X-ray source of precisely the geoemetric form required for FCT. Ultimately we envisage these techniques being integrated within a single imaging/DEXA/scatter system to provide a comprehensive diagnostic tool. The nature of the techniques also enables design towards hand portable devices for point-of-patient care. Thus this proposal principally concerns the development of a new instrument that will be subsequently used to examine the possibilities of applying our novel technologies to a number of different areas and therefore it will enable a new and exciting research capability.
|
Key Findings |
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
|
Potential use in non-academic contexts |
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
|
Impacts |
Description |
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk |
Summary |
|
Date Materialised |
|
|
Sectors submitted by the Researcher |
This information can now be found on Gateway to Research (GtR) http://gtr.rcuk.ac.uk
|
Project URL: |
|
Further Information: |
|
Organisation Website: |
http://www.cranfield.ac.uk |